103 research outputs found

    Minimal time change detection algorithm for reconfigurable control system and application to aerospace

    Get PDF
    System parameters should be tracked on-line to build a reconfigurable control system even though there exists an abrupt change. For this purpose, a new performance index that we are studying is the speed of adaptation- how quickly does the system determine that a change has occurred? In this paper, a new, robust algorithm that is optimized to minimize the time delay in detecting a change for fixed false alarm probability is proposed. Simulation results for the aircraft lateral motion with a known or unknown change in control gain matrices, in the presence of doublet input, indicate that the algorithm works fairly well. One of its distinguishing properties is that detection delay of this algorithm is superior to that of Whiteness Test

    The minimal time detection algorithm

    Get PDF
    An aerospace vehicle may operate throughout a wide range of flight environmental conditions that affect its dynamic characteristics. Even when the control design incorporates a degree of robustness, system parameters may drift enough to cause its performance to degrade below an acceptable level. The object of this paper is to develop a change detection algorithm so that we can build a highly adaptive control system applicable to aircraft systems. The idea is to detect system changes with minimal time delay. The algorithm developed is called Minimal Time-Change Detection Algorithm (MT-CDA) which detects the instant of change as quickly as possible with false-alarm probability below a certain specified level. Simulation results for the aircraft lateral motion with a known or unknown change in control gain matrices, in the presence of doublet input, indicate that the algorithm works fairly well as theory indicates though there is a difficulty in deciding the exact amount of change in some situations. One of MT-CDA distinguishing properties is that detection delay of MT-CDA is superior to that of Whiteness Test

    Switching LPV Control of an F-16 Aircraft via Controller State Reset

    Get PDF
    In flight control, the design objective and the aircraft dynamics may be different in low and high angle of attack regions. This paper presents a systematic switching Linear Parameter-varying LPV method to determine if it is practical to use for flight control designs over a wide angle of attack region. The approach is based on multiple parameter-dependent Lyapunov functions a family of LPV controllers are designed, and each of them is suitable for a specific parameter subspace. The state of the controller is reset to guarantee the stability requirement of the Lyapunov function when the switching event occurs. Two parameter-dependent switching logics, hysteresis switching and switching with average dwell times are examined. The proposed switching LPV control scheme is applied to an F-16 aircraft model with different design objectives and aircraft dynamics in low and high angle of attack regions. The nonlinear simulating results using both switching logics are compared

    Tool to visualize and evaluate operator proficiency in laser hair-removal treatments

    Get PDF
    BACKGROUND: The uniform delivery of laser energy is particularly important for safe and effective laser hair removal (LHR) treatment. Although it is necessary to quantitatively assess the spatial distribution of the delivered laser, laser spots are difficult to trace owing to a lack of visual cues. This study proposes a novel preclinic tool to evaluate operator proficiency in LHR treatment and applies this tool to train novice operators and compare two different treatment techniques (sliding versus spot-by-spot). METHODS: A simulation bed is constructed to visualize the irradiated laser spots. Six novice operators are recruited to perform four sessions of simulation while changing the treatment techniques and the presence of feedback (sliding without feedback, sliding with feedback, spot-by-spot without feedback, and spot-by-spot with feedback). Laser distribution maps (LDMs) are reconstructed through a series of images processed from the recorded video for each simulation session. Then, an experienced dermatologist classifies the collected LDMs into three different performance groups, which are quantitatively analyzed in terms of four performance indices. RESULTS: The performance groups are characterized by using a combination of four proposed indices. The best-performing group exhibited the lowest amount of randomness in laser delivery and accurate estimation of mean spot distances. The training was only effective in the sliding treatment technique. After the training, omission errors decreased by 6.32% and better estimation of the mean spot distance of the actual size of the laser-emitting window was achieved. Gels required operators to be trained when the spot-by-spot technique was used, and imposed difficulties in maintaining regular laser delivery when the sliding technique was used. CONCLUSIONS: Because the proposed system is simple and highly affordable, it is expected to benefit many operators in clinics to train and maintain skilled performance in LHR treatment, which will eventually lead to accomplishing a uniform laser delivery for safe and effective LHR treatment

    Orion Crew Exploration Vehicle Launch Abort System Guidance and Control Analysis Overview

    Get PDF
    Aborts during the critical ascent flight phase require the design and operation of Orion Crew Exploration Vehicle (CEV) systems to escape from the Crew Launch Vehicle (CLV) and return the crew safely to the Earth. To accomplish this requirement of continuous abort coverage, CEV ascent abort modes are being designed and analyzed to accommodate the velocity, altitude, atmospheric, and vehicle configuration changes that occur during ascent. Aborts from the launch pad to early in the flight of the CLV second stage are performed using the Launch Abort System (LAS). During this type of abort, the LAS Abort Motor is used to pull the Crew Module (CM) safely away from the CLV and Service Module (SM). LAS abort guidance and control studies and design trades are being conducted so that more informed decisions can be made regarding the vehicle abort requirements, design, and operation. This paper presents an overview of the Orion CEV, an overview of the LAS ascent abort mode, and a summary of key LAS abort analysis methods and results

    Exploring the Category and Use Cases on Digital Therapeutic Methodologies

    Get PDF
    Objectives As the Fourth Industrial Revolution advances, there is a growing interest in digital technology. In particular, the use of digital therapeutics (DTx) in healthcare is anticipated to reduce medical expenses. However, analytical research on DTx is still insufficient to fuel momentum for future DTx development. The purpose of this article is to analyze representative cases of different types of DTx from around the world and to propose a classification system. Methods In this exploratory study examining DTx interaction types and representative cases, we conducted a literature review and selected seven interaction types that were utilized in a large number of cases. Then, we evaluated the specific characteristics of each DTx mechanism by reviewing the relevant literature, analyzing their indications and treatment components. A representative case for each mechanism was provided. Results Cognitive behavioral therapy, distraction therapy, graded exposure therapy, reminiscence therapy, art therapy, therapeutic exercise, and gamification are the seven categories of DTx interaction types. Illustrative examples of each variety are provided. Conclusions Efforts from both the government and private sector are crucial for success, as standardization can decrease both the expense and the time required for government-led DTx development. The private sector should partner with medical facilities to stimulate potential demand, carry out clinical research, and produce scholarly evidence

    Federated learning for thyroid ultrasound image analysis to protect personal information: Validation study in a real health care environment

    Get PDF
    Background: Federated learning is a decentralized approach to machine learning; it is a training strategy that overcomes medical data privacy regulations and generalizes deep learning algorithms. Federated learning mitigates many systemic privacy risks by sharing only the model and parameters for training, without the need to export existing medical data sets. In this study, we performed ultrasound image analysis using federated learning to predict whether thyroid nodules were benign or malignant. Objective: The goal of this study was to evaluate whether the performance of federated learning was comparable with that of conventional deep learning. Methods: A total of 8457 (5375 malignant, 3082 benign) ultrasound images were collected from 6 institutions and used for federated learning and conventional deep learning. Five deep learning networks (VGG19, ResNet50, ResNext50, SE-ResNet50, and SE-ResNext50) were used. Using stratified random sampling, we selected 20% (1075 malignant, 616 benign) of the total images for internal validation. For external validation, we used 100 ultrasound images (50 malignant, 50 benign) from another institution Results: For internal validation, the area under the receiver operating characteristic (AUROC) curve for federated learning was between 78.88% and 87.56%, and the AUROC for conventional deep learning was between 82.61% and 91.57%. For external validation, the AUROC for federated learning was between 75.20% and 86.72%, and the AUROC curve for conventional deep learning was between 73.04% and 91.04%. Conclusions: We demonstrated that the performance of federated learning using decentralized data was comparable to that of conventional deep learning using pooled data. Federated learning might be potentially useful for analyzing medical images while protecting patients personal information. © 2021 JMIR Medical Informatics. All rights reserved.1

    A development of assistant surgical robot system based on surgical-operation-by-wire and hands-on-throttle-and-stick

    Get PDF
    BACKGROUND: Robot-assisted laparoscopic surgery offers several advantages compared with open surgery and conventional minimally invasive surgery. However, one issue that needs to be resolved is a collision between the robot arm and the assistant instrument. This is mostly caused by miscommunication between the surgeon and the assistant. To resolve this limitation, an assistant surgical robot system that can be simultaneously manipulated via a wireless controller is proposed to allow the surgeon to control the assistant instrument. METHODS: The system comprises two novel master interfaces (NMIs), a surgical instrument with a gripper actuated by a micromotor, and 6-axis robot arm. Two NMIs are attached to master tool manipulators of da Vinci research kit (dVRK) to control the proposed system simultaneously with patient side manipulators of dVRK. The developments of the surgical instrument and NMI are based on surgical-operation-by-wire concept and hands-on-throttle-and-stick concept from the earlier research, respectively. Tests for checking the accuracy, latency, and power consumption of the NMI are performed. The gripping force, reaction time, and durability are assessed to validate the surgical instrument. The workspace is calculated for estimating the clinical applicability. A simple peg task using the fundamentals of laparoscopic surgery board and an in vitro test are executed with three novice volunteers. RESULTS: The NMI was operated for 185 min and reflected the surgeon’s decision successfully with a mean latency of 132 ms. The gripping force of the surgical instrument was comparable to that of conventional systems and was consistent even after 1000 times of gripping motion. The reaction time was 0.4 s. The workspace was calculated to be 8397.4 cm(3). Recruited volunteers were able to execute the simple peg task within the cut-off time and successfully performed the in vitro test without any collision. CONCLUSIONS: Various experiments were conducted and it is verified that the proposed assistant surgical robot system enables collision-free and simultaneous operation of the dVRK’s robot arm and the proposed assistant robot arm. The workspace is appropriate for the performance of various kinds of surgeries. Therefore, the proposed system is expected to provide higher safety and effectiveness for the current surgical robot system

    LPV Controller Interpolation for Improved Gain-Scheduling Control Performance

    No full text
    In this paper, a new gain-scheduling control design approach is proposed by combining LPV (linear parameter-varying) control theory with interpolation techniques. The improvement of gain-scheduled controllers can be achieved from local synthesis of Lyapunov functions and continuous construction of a global Lyapunov function by interpolation. It has been shown that this combined LPV control design scheme is capable of improving closed-loop performance derived from local performance improvement. The gain of the LPV controller will also change continuously across parameter space. The advantages of the newly proposed LPV control is demonstrated through a detailed AMB controller design example
    corecore